Ein Sicherheitssystem besteht immer aus drei Teilen: Matte, Schaltgerät und Abschlusswiderstand. Das SG-EFS ist das Gegenstück zu Mayser-Matten, wie sie an IMA-Maschinen liegen – eine Bircher-Matte läuft daran nicht.
Prüfen Sie vor dem Tausch, wie viele getrennte Schutzzonen die Anlage hat. Zwei Tischfelder brauchen zwei unabhängige Signalgeberkreise.
Trittmatten & Sicherheitsschaltmatten – Bezeichnung lesen, Zonen, Montage→
Bircher Reglomat ESD3-6171 safety relay
Technical details:
• Manufacturer: Bircher Reglomat AG
• Model: ESD3-6171
• Type: Safety relay
• Category: Cat.3 (EN 954-1)
• Response time: max. 50ms
• Operating voltage: 24V AC/DC ±10% 50Hz
• Load current: 2A / 250VAC
• Q-CH-NR: 0708020011
• Version: V8
• Weight: approx. 150g
• Dimensions: 22.5 x 99 x 114.5 mm
Areas of application:
• The Bircher Reglomat ESD3-6171 safety relay is used in safety circuits of machines and systems to ensure safe shutdown in the event of danger. It is used in industrial automation and in safety systems for machines.
Special features:
• High safety according to category 3 (EN 954-1)
• Fast response time of max. 50ms
• Reliable function with an operating voltage of 24V AC/DC
• Robust design for use in industrial environments
Used device removed from a running system.
Operating voltage:
• 24 V AC ±10%, 50/60 Hz
• 24VDC ±10%
• 115V AC ±10%, 60Hz
• 230 V AC ±10%, 50 Hz
• Power consumption: Max. 5 VA
• Safety outputs:
• Use category according to EN 60947-4-1:
• AC-1: 230 V/2 A/460 VA, approx. 280,000 switching cycles
• DC-1: 24 V/2 A/48 W, approx. 500,000 switching cycles
• Usage category according to EN 60947-5-1:
• AC-15: 230 V/2 A/460 VA, approx. 150,000 switching cycles
• DC-13: 24 V/2 A/48 W, approx. 80,000 switching cycles
• Contact protection: Internal 2 A slow
• Service life: Mechanical 10 million switching cycles
• Response time: < 50 ms
Status relay:
• Switching capacity:
• 24 V DC / 1 A, resistive load
• 30V AC / 1A, resistive load
Environmental conditions:
• Protection class: IP20 (EsGate, ESD3), IP30 (ESR3)
• Operating temperature:
• EsGate: -20 °C to +60 °C
• ESD3: -20 °C to +55 °C
• ESR3: -20 °C to +50 °C
• Storage temperature:
• EsGate: -40 °C to +70 °C
• ESD3, ESR3: -20 °C to +80 °C
• Humidity:
• EsGate: Max. 95% relative, non-condensing
• ESD3, ESR3: Max. 80% relative, non-condensing
Areas of application
The ESD3-6171 safety relay is used in various safety-critical applications including:
• Machine protection: Protection of danger zones on machines.
• Gate controls: Securing gates and doors in industrial environments.
• Safety circuits: Integration into safety circuits for machine control.
Special features
• High safety according to category 3 (EN 954-1)
• Fast response time of max. 50ms
• Reliable function with an operating voltage of 24V AC/DC
• Robust design for use in industrial environments
• Forced relays and redundant signal evaluation
• Mounting on DIN rail
For downloads and further information, see Downloads or https://smartaccess.bircher.com/de/
Goods tariff number
The corresponding HS Code (commodity tariff number) for safety relays is: 8536.49
-
Condition
-
Manufacturer Part No.
-
Product Category
-
Manufacturer
-
Weight